Unique Pump Systems, Kailash Industrial Complex, Vikhroli (W)
Reviewed by the Unique Pump Systems engineering team | Updated November 2026
Quick Answer: An agitator (mixer or reactor) mechanical seal differs from a pump seal because it usually seals vapour or gas at the top of a vessel, runs at low speed with large shaft runout, and must handle pressure and vacuum. For non-hazardous duties at low pressure, a single dry-running seal can be used. For toxic, flammable, sterile or pressurised reactors, use a double mechanical seal with a pressurised barrier fluid from a thermosyphon or pressure pot, typically kept about 1.5 to 2 bar above the vessel pressure. A cartridge seal with its own bearing helps absorb shaft deflection.
Reactors and agitated vessels in chemical, pharma, API, paint and food plants depend on the agitator shaft seal to keep the process in and the atmosphere out. A pump seal design simply fitted to an agitator often fails quickly, because the operating conditions are very different. This guide explains those differences and how to choose the right mechanical seal for top-entry and bottom-entry agitators.
| Factor | Pump seal | Agitator seal (top-entry) |
|---|---|---|
| What the faces see | Liquid | Mostly vapour, gas or foam |
| Lubrication from process | Yes | Usually no; needs barrier fluid or dry-running faces |
| Shaft speed | High (typically 1450 to 2900 RPM) | Low (often under 200 RPM) |
| Shaft runout and deflection | Small | Larger, due to long overhung shafts and mixing loads |
| Pressure | Positive | Positive, atmospheric or vacuum, sometimes all in one batch |
| Shaft size | Small to medium | Often large |
| Cleaning and sterilisation | Sometimes | Often (CIP/SIP in pharma and food) |
A single seal with face materials designed to run without liquid lubrication, often carbon against silicon carbide with special geometry. Suitable for non-toxic, non-flammable products at low pressure, such as many food and water-based mixing duties.
Two seals in series with a barrier fluid between them, kept at a higher pressure than the vessel. Any leakage is barrier fluid moving into the vessel or to atmosphere, not product escaping. This is the standard choice for solvents, toxic chemicals, APIs and pressurised reactors. It is the agitator equivalent of API Plan 53-type arrangements used on pumps.
The fluid between the seals is at a lower pressure than the vessel. Used where some product leakage into the buffer is acceptable and can be detected.
The faces are separated by a thin film of nitrogen or another gas. Used in sterile and pharma duties where liquid barrier fluid contamination is not acceptable.
The seal, sleeve and gland are pre-assembled. An integral bearing supports the shaft at the seal, reducing the effect of shaft deflection on the faces. Installation errors are greatly reduced.
A double seal needs a supply system that keeps the barrier fluid pressurised, cool and topped up.
| System | How it works | Typical use |
|---|---|---|
| Thermosyphon vessel | A small vessel above the seal, pressurised with nitrogen. Natural circulation (thermosyphon) carries warm fluid up and cool fluid down, often through a cooling coil | Most chemical and pharma reactors |
| Pressure pot with hand pump | Simple pressurised reservoir topped up manually | Smaller or lower-duty reactors |
| Forced circulation unit | A pump circulates barrier fluid through a cooler | Large seals, high heat load, high speed |
| Problem | Likely cause | Fix |
|---|---|---|
| Barrier fluid level drops quickly | Inboard seal leaking into vessel; outboard seal leaking to atmosphere | Inspect faces; check runout and seal setting |
| Product found in barrier fluid | Barrier pressure lost or too low | Restore nitrogen supply; check pressure setting |
| Seal overheating | Poor thermosyphon circulation; cooling water off; wrong piping slopes | Check cooling and piping layout; vent the system |
| Face damage after vacuum batch | Faces opening under reverse pressure | Use a seal designed for vacuum and pressure reversal |
| Wear track wider than face | Shaft runout or deflection | Check gearbox bearings; fit seal with integral bearing |
| Crystallised product at seal | Product drying at inboard faces | Use flushing, quench or a design that keeps product away from faces |
Read More: Centrifugal Pump Troubleshooting Guide
Gland packing is still used on simple open-top mixers. It is cheap but allows emissions, needs regular adjustment and cannot hold vacuum reliably. For closed reactors, solvents, odours and GMP requirements, a mechanical seal is the better long-term choice.
The same plant that runs reactors usually runs transfer and process pumps too. A Centrifugal Pump circulating cooling water, a gear pump dosing solvents or a lobe pump transferring viscous batches all need seals matched to their duty. For drum and tank transfer of flammable solvents where no seal is preferred, an aodd pump is a seal-less option.
Unique Pump Systems manufactures and supplies mechanical seals for pumps and process equipment. Share your agitator details for a seal recommendation.
An agitator mechanical seal seals the rotating shaft of a mixer, agitator or reactor where it enters the vessel. It keeps the process inside and the atmosphere out, and is designed for low speed, large shaft movement and, in top-entry designs, a vapour environment.
A pump seal runs in liquid at high speed with little shaft movement. A top-entry agitator seal usually runs in vapour at low speed, with more shaft runout and deflection, and often has to handle both pressure and vacuum.
Use a double seal with a pressurised barrier fluid for toxic, flammable, odorous or sterile products, for pressurised reactors and wherever product emissions are not acceptable.
A thermosyphon system is a small pressurised vessel connected to a double seal. Natural circulation moves warm barrier fluid up to the vessel and cool fluid back down to the seal, often through a cooling coil, keeping the seal lubricated, cool and pressurised.
Typically about 1.5 to 2 bar above the maximum vessel pressure, so that any leakage is barrier fluid moving into the vessel rather than product escaping. Always follow the seal manufacturer's recommendation.
Choose a fluid compatible with the product and process, such as white oil, glycol-water or a food-grade fluid. In pharma and food duties, the fluid must be acceptable if small amounts enter the batch.
Yes, a single dry-running seal can be used for non-hazardous products at low pressure. For hazardous, pressurised or sterile duties, a double seal is recommended.
Common causes are excessive shaft runout from worn gearbox bearings, loss of barrier pressure, poor thermosyphon cooling, vacuum opening the faces and product crystallising at the faces.
Agitator and reactor seals face conditions that pump seals do not: vapour instead of liquid, slow speed, large shaft movement and changing pressure. Single dry-running seals suit simple, low-pressure, non-hazardous duties. Double seals with a pressurised barrier fluid, supported by a thermosyphon or pressure pot, are the safe choice for hazardous, sterile or pressurised reactors.
Contact Unique Pump Systems with your agitator and process details and we will help you choose the right seal and support system.