Unique Pump Systems, Kailash Industrial Complex, Vikhroli (W)
Reviewed by the Unique Pump Systems engineering team | Updated November 2026
Quick Answer: A thermic fluid pump (hot oil circulation pump) is usually an end-suction centrifugal pump built for temperatures up to about 300°C to 350°C, with a ductile iron or cast steel casing, an air-cooled or heat-barrier seal housing and a high-temperature mechanical seal. Size it from the heater duty: Flow (m³/s) = Heat load (kW) ÷ (density × specific heat × ΔT), typically with a 20°C to 40°C temperature drop across the system. Size the motor for cold start-up, when the oil is heavier and more viscous.
Thermic fluid heaters (hot oil systems) are used across Indian process industries: chemicals, pharma, textiles, food, plywood, rubber and bitumen plants. The circulation pump is the heart of the system. If it fails, heating stops and the heater can overheat. If it leaks, hot oil becomes a fire hazard. This guide explains how to select, size and look after a thermic fluid pump.
A thermic fluid system heats a synthetic or mineral heat-transfer oil in a heater (fired by gas, oil, coal, biomass or electricity) and pumps it around a closed loop to process equipment such as reactors, dryers, presses and storage tanks. The oil releases heat and returns to the heater. Because the oil stays liquid at high temperature without high pressure, it can deliver 250°C to 300°C+ heat at low system pressure, unlike steam.
The loop typically includes the heater, a circulation pump, an expansion tank, a deaerator, filters and the user equipment.
| Challenge | Effect on the pump | Design answer |
|---|---|---|
| Very high temperature (up to about 300°C to 350°C) | Thermal expansion, seal and bearing heat | Air-cooled or finned bearing bracket and seal housing; heat barrier |
| Cold start-up | Oil is thicker and denser; higher power demand | Motor sized for cold oil; gradual warm-up |
| Fire risk from leaks | Hot oil leaks can ignite | High-temperature mechanical seal or seal-less design; leak-tight gaskets |
| Thermal shock | Rapid temperature change can crack brittle casings | Ductile iron or cast steel instead of grey cast iron |
| Oil degradation (coking) | Deposits on seal faces and impeller | Correct flow through the heater; good seal design; oil testing |
| Air and moisture at start-up | Vapour, noise, cavitation | Proper deaeration and slow heat-up |
| Factor | Centrifugal pump | Gear pump |
|---|---|---|
| Typical role | Main circulation pump | Filling, draining, transfer, small heaters and high-viscosity hot oils |
| Flow range | Medium to very large | Small to medium |
| Pressure needed | Low to moderate (enough to overcome heater and system losses) | Moderate to high |
| Behaviour with viscosity changes | Flow and head change as oil warms | Steady flow regardless of viscosity |
| Protection | Safe against a closed valve for short periods | Needs a relief valve |
For main circulation, a high-temperature Centrifugal Pump is the usual choice. A jacketed or high-temperature gear pump is common for filling the system, transferring thermic oil and handling viscous heated liquids.
Other pumps have a place around the heater too: an aodd pump is handy for draining and emptying drums of used thermic oil, and a lobe pump can transfer viscous heated products on the process side once they leave the heated vessels.
Q (m³/s) = P (kW) ÷ (ρ (kg/m³) × cp (kJ/kg·K) × ΔT (K))
P = heater output; ρ and cp = density and specific heat of the oil at operating temperature; ΔT = temperature drop between heater outlet and return
1,000,000 kcal/hr ≈ 1,163 kW
Example: a 10 lakh kcal/hr (about 1,163 kW) heater, thermic oil at about 250°C with density about 780 kg/m³ and specific heat about 2.4 kJ/kg·K, and a design ΔT of 20°C:
Use the oil supplier's data sheet for density and specific heat at your temperature. A smaller ΔT needs more flow; heater makers usually specify the minimum flow to protect the coil from overheating.
Add the pressure drop across the heater coil (from the heater maker), the user equipment, pipes, valves, filters and fittings. Convert pressure to head using the oil's density at operating temperature: head (m) = pressure (bar) × 10.2 ÷ specific gravity.
At ambient temperature, thermic oil is denser and much more viscous than at 250°C. A centrifugal pump will draw more power when cold. Size the motor for the cold condition, or use a VFD to start slowly and warm the system gradually.
Hot oil has a higher vapour pressure, and dissolved air or moisture comes out during heating. Place the pump so it has a positive suction head from the expansion tank, keep suction lines short and size them generously.
Read More: Centrifugal Pump Cavitation: NPSH Explained
The shaft seal is the most critical component, because a leak releases oil that may be above its flash point.
| Seal option | Notes |
|---|---|
| High-temperature mechanical seal | Silicon carbide or carbon faces with graphite or high-temperature secondary seals; mounted in a cooled seal chamber |
| Seal with steam or nitrogen quench | Prevents oil coking on the atmospheric side |
| Gland packing (graphite) | Older designs; needs controlled leakage, which is undesirable with hot oil |
| Magnetic drive (seal-less) | No dynamic shaft seal; used where zero leakage is critical |
Read More: Types of Mechanical Seals
Safety: hot thermic oil can ignite if it leaks onto hot surfaces or insulation. Repair leaks promptly, replace oil-soaked insulation and keep fire protection in place around the heater and pump.
| Problem | Likely cause | Fix |
|---|---|---|
| Seal leakage | Coking on faces, wrong seal, overheating, dry running at start-up | Use a high-temperature seal with cooling or quench; vent properly before start |
| Noise and fluctuating pressure at start-up | Moisture or air flashing off | Slow heat-up with a hold at around 100°C to 120°C; vent through expansion tank |
| Motor tripping when cold | Motor sized for hot oil only | Upsize motor or start with a VFD and warm-up cycle |
| Bearing failure | Heat transfer from pump to bearings; poor lubrication | Check cooling fins and airflow; use high-temperature grease or oil |
| Heater coil overheating alarm | Low circulation flow | Check pump performance, filters and valve positions |
Unique Pump Systems supplies centrifugal pumps, gear pumps and mechanical seals for hot oil and heated liquid duties. Share your heater details and we will recommend the right pump and seal.
A thermic fluid pump, also called a hot oil pump, circulates heat-transfer oil between a thermic fluid heater and process equipment. It is usually a centrifugal pump designed for temperatures up to about 300 to 350 degrees Celsius.
An end-suction centrifugal pump with an air-cooled or heat-barrier design and a high-temperature mechanical seal is normally used for main circulation. Gear pumps are used for filling, transfer and small or high-viscosity duties.
Divide the heater output in kW by the product of oil density, specific heat and the design temperature drop. For example, a 1,163 kW heater with 780 kg/m3 oil, 2.4 kJ/kg K specific heat and a 20 degree drop needs about 112 m3/hr.
Ductile (SG) iron or cast steel casings are common because they handle thermal stress better than grey cast iron. Gaskets are usually graphite or spiral-wound, and seals use high-temperature face and secondary materials.
Cold thermic oil is denser and more viscous, so the pump draws more power. If the motor was sized only for hot oil, it can overload. Upsizing the motor or using a VFD with a controlled warm-up solves this.
A high-temperature mechanical seal with silicon carbide or carbon faces, mounted in a cooled seal chamber, is common. Quench arrangements or magnetic drive pumps are used where leakage must be minimised.
Moisture and air in new or topped-up oil flash into vapour as the system heats, causing noise and pressure swings. Holding the temperature around 100 to 120 degrees Celsius and venting through the expansion tank removes it.
Yes, for filling and draining systems, transferring thermic oil and in small heaters. Large circulation duties normally use centrifugal pumps.
A thermic fluid pump must handle high temperature, cold start-up and leak-free sealing all at once. Size the flow from the heater duty and temperature drop, check head and NPSH at operating temperature, size the motor for cold oil, and choose ductile iron or cast steel construction with a high-temperature seal. Follow a careful warm-up procedure and the pump will run safely for years.
Contact Unique Pump Systems with your heater and oil details for a pump and seal recommendation.