Unique Pump Systems, Kailash Industrial Complex, Vikhroli (W)

Unique Pump Systems, Kailash Industrial Complex, Vikhroli (W)

AODD Pump for Hazardous Areas

Home Blog AODD Pump for Hazardous Areas

AODD Pumps for Hazardous Areas and Flammable Liquids: ATEX, Earthing and Safe Selection

AODD Pump for Hazardous Areas and Flammable Liquids

Reviewed by the Unique Pump Systems engineering team | Updated November 2026

Quick Answer: AODD pumps are widely used for flammable solvents, fuels, paints and inks because they are driven by compressed air and have no electric motor or rotating shaft seal at the pump. To be safe in a hazardous area, the pump must also control static electricity: use conductive construction (stainless steel, aluminium or conductive plastics), earth (ground) the pump with a dedicated earthing lug, bond hoses and containers, and use only Ex-rated accessories. In ATEX terms, a pump marked Ex II 2 G is suitable for Zone 1 gas areas; check the temperature class (T-rating) against your liquid and area.

Solvent transfer, drum emptying and paint circulation are among the most common jobs for an aodd pump. These are also some of the most dangerous duties in a plant, because a single spark in a flammable atmosphere can cause a fire or explosion. Being air-driven is a big advantage, but it is not enough on its own. This guide explains what makes an AODD pump safe in hazardous areas, how to read ATEX markings and what to check before you buy or install one.

Key Takeaways

  • Air drive removes the electric motor from the hazardous area, but static electricity remains a real ignition risk.
  • Non-conductive plastic pumps can build up static charge when pumping solvents. Use conductive materials for flammable liquids.
  • Every pump, hose and container must be earthed and bonded.
  • Match the pump's ATEX category and temperature class to the zone and the liquid.
  • Accessories such as solenoid valves, stroke counters and leak sensors must also be rated for the zone.

Safety note: this guide is general information. Hazardous area classification, equipment selection and installation must follow your site's safety rules, applicable standards and the requirements of the authority having jurisdiction. In India, equipment for petroleum and explosive areas may also need approval from PESO (Petroleum and Explosives Safety Organisation).

Why AODD Pumps Suit Flammable Liquids

  • No electric motor at the pump, so no motor sparks or hot motor surfaces in the zone.
  • No rotating shaft seal, so no seal faces generating frictional heat and no seal leak path.
  • Runs dry without damage, so drum emptying will not overheat the pump.
  • Stalls against a closed valve, so no overpressure and no heat build-up from a dead-headed pump.
  • Portable and easy to move between drums, tanks and areas.

For a general comparison, see AODD Pump vs Centrifugal Pump.

Hazardous Area Zones Explained

ZoneAtmosphereHow often present
Zone 0Explosive gas or vapourContinuously or for long periods (for example inside a solvent tank)
Zone 1Explosive gas or vapourLikely in normal operation (for example around drum filling points)
Zone 2Explosive gas or vapourNot likely in normal operation, and only briefly if it occurs
Zones 20, 21, 22Combustible dustSame frequency levels as 0, 1 and 2, for dust

How to Read an ATEX Marking

A typical ATEX marking on an AODD pump looks like: Ex II 2 G Ex h IIB T4 Gb. Here is what each part means:

MarkingMeaning
Ex (in a hexagon)Equipment for explosive atmospheres
IIEquipment group II: surface industries (not mining)
2Category 2: suitable for Zone 1 (gas) or Zone 21 (dust); Category 1 suits Zone 0/20; Category 3 suits Zone 2/22
G / DGas or dust atmosphere
Ex hNon-electrical equipment protection concept
IIA / IIB / IICGas group; IIC (for example hydrogen) is the most demanding
T1 to T6Temperature class; maximum surface temperature (T4 = 135°C, T6 = 85°C)
Ga / Gb / GcEquipment protection level, matching Zone 0 / 1 / 2

Important: an AODD pump's surface temperature depends on the liquid temperature. The pump's temperature class is only valid within the maximum liquid temperature stated by the manufacturer.

Static Electricity: The Hidden Ignition Source

When non-conductive liquids such as hydrocarbon solvents flow through pipes, hoses and pumps, they generate static charge. If the charge cannot drain to earth, it can build up until it discharges as a spark. In an air-operated pump, the main ways to manage this are:

  • Conductive pump materials: stainless steel, aluminium, or plastics made conductive with carbon (for example conductive polypropylene, acetal or PVDF).
  • Earthing (grounding) lug: connect the pump to a verified earth point with a suitable earthing cable.
  • Bonding: connect pump, hoses, drums, tanks and receiving vessels so they are all at the same potential.
  • Conductive or static-dissipative hoses: with continuity checked regularly.
  • Diaphragm and ball materials: follow the manufacturer's guidance on which elastomer and PTFE parts are permitted in the zone.

Never use a standard non-conductive plastic AODD pump for flammable solvents in a hazardous area. Choose a conductive version and earth it.

For general material choices, see AODD Diaphragm Material Selection: PTFE vs Santoprene.

Material Choice for Hazardous Duties

Pump body materialConductive?Notes
Stainless steel (SS 316)YesGood corrosion resistance; common for solvents, pharma and chemicals
AluminiumYesEconomical for paints, inks, fuels; some light alloys are restricted in the most demanding categories (Zone 0)
Cast ironYesFor non-corrosive solvents and oils
Conductive polypropylene, acetal or PVDFYes (when carbon-filled)For corrosive chemicals in hazardous areas
Standard polypropylene or PVDFNoNot suitable for flammable liquids in hazardous areas

Installation Checklist for Hazardous Areas

  • Confirm the area classification (zone, gas group, temperature class) from the site's hazardous area drawing
  • Select a pump with matching ATEX category and documentation
  • Earth the pump with a dedicated cable to a verified earth point; test continuity
  • Bond hoses, drums, IBCs and tanks; use conductive hoses
  • Use Ex-rated solenoid valves, stroke counters and leak detection sensors
  • Pipe the exhaust air to a safe area, because a ruptured diaphragm can release solvent vapour into the exhaust
  • Use clean, dry air and do not exceed the rated maximum air pressure
  • Keep the liquid temperature within the pump's stated limit for its temperature class

Maintenance in Hazardous Areas

  • Check earthing cables and hose continuity at every inspection
  • Replace diaphragms on a schedule to avoid ruptures that release solvent into the exhaust
  • Use only original or approved spare parts to keep the certification valid
  • Never strike aluminium or steel parts with tools that can create sparks; use non-sparking tools where required
  • Depressurise air and liquid and drain the pump before any work

For general fault-finding, see our AODD pump troubleshooting guide.

Alternatives for Hazardous Duties

AODD pumps are not the only option. For continuous solvent transfer at steady flow, a gear pump with a flameproof motor and a suitable mechanical seal or magnetic drive can be more energy efficient. For large flows of thin solvents, a Centrifugal Pump with a flameproof motor may suit. For viscous food or cosmetic products in classified areas, a lobe pump with a flameproof drive is also used.

Information to Share With Your Supplier

  • Liquid name, flash point and temperature
  • Area classification: zone, gas group and temperature class
  • Flow rate, discharge pressure and suction conditions
  • Material preference (SS, aluminium, conductive plastic)
  • Accessories needed (solenoid, stroke counter, leak detector, dampener)
  • Any PESO or other approval requirements

Unique Pump Systems supplies AODD pumps in metal and plastic constructions. Share your hazardous area details and ask our team about conductive construction, earthing options and available certification documents for your duty.

Frequently Asked Questions

Are AODD pumps safe for flammable liquids?

Yes, when correctly selected and installed. AODD pumps are air-driven and have no motor or rotating seal at the pump, but they must be made of conductive materials, properly earthed and bonded, and rated for the hazardous area zone.

What does ATEX mean for an AODD pump?

ATEX is the European framework for equipment used in explosive atmospheres. An ATEX-marked AODD pump has been assessed for use in a specific zone category, gas or dust group and temperature class, shown in its marking such as Ex II 2 G.

Which ATEX category is needed for Zone 1?

Category 2 equipment, marked for example Ex II 2 G, is suitable for Zone 1 gas areas. Category 1 is needed for Zone 0, and Category 3 is the minimum for Zone 2.

Why must an AODD pump be earthed?

Flowing solvents and other non-conductive liquids generate static electricity. If the pump is not earthed, charge can build up and discharge as a spark that can ignite flammable vapour.

Can I use a plastic AODD pump for solvents?

Only if it is made of a conductive plastic, such as carbon-filled polypropylene, acetal or PVDF, and properly earthed. Standard non-conductive plastic pumps are not suitable for flammable liquids in hazardous areas.

What is the temperature class on an ATEX pump?

The temperature class, from T1 to T6, shows the maximum surface temperature of the equipment. For example, T4 means a maximum of 135 degrees Celsius. On an AODD pump, it is valid only up to the maximum liquid temperature stated by the manufacturer.

Do AODD pump accessories need to be ATEX rated?

Yes. Solenoid valves, stroke counters, leak detectors and any other electrical accessories installed in the hazardous area must be rated for that zone.

Is PESO approval needed for pumps in India?

Equipment used in petroleum and explosive areas in India may need PESO approval depending on the application and site requirements. Check with your safety team and the authority having jurisdiction.

Conclusion

AODD pumps are a natural fit for flammable liquids, but safety depends on the details: conductive construction, proper earthing and bonding, the right ATEX category and temperature class, Ex-rated accessories and exhaust piped to a safe area. Get these right, and an AODD pump is one of the safest and simplest ways to move solvents, fuels and paints.

Contact Unique Pump Systems with your liquid and area classification, and we will help you choose a suitable AODD pump configuration.

Unique Pump Systems

Kailash Industrial Complex, Vikhroli West, Mumbai

★★★★★4.4 out of 5 — Rated by verified clients on Google

"Excellent quality gear pumps. Delivered on time, every time. Highly recommend for industrial applications."

— Verified Google Review

"Best mechanical seal manufacturer in Mumbai. Replaced our imported seal with their local equivalent — same performance, much better pricing."

— Verified Google Review
Write a Review on Google View on Google Maps
Rated 4.4★ on Google
★★★★★
See our reviews →