Quick Answer: A gear pump relief valve protects the pump, motor and pipework from overpressure. Because a gear pump is positive displacement, it keeps pushing liquid even when the discharge is blocked, so pressure rises until something fails. The relief valve opens at a set pressure and returns flow to the suction or to the tank. A common rule is to set it about 10% to 20% above the maximum normal operating pressure, and always below the rated pressure of the pump and system. An internal relief valve is for short-term protection only; continuous bypass needs an external valve returning to the tank.
Almost every gear pump needs a relief valve, yet it is one of the most misunderstood parts of a pumping system. Set too low, it wastes flow and heats the liquid. Set too high, or blocked, it offers no protection at all. This guide explains how gear pump relief valves work, the difference between internal and external valves, how to set the pressure correctly, and how to diagnose common relief valve problems.
A centrifugal pump that runs against a closed valve simply reaches its shut-off head. A gear pump does not have a shut-off point. Each revolution moves a fixed volume of liquid, so if the discharge is closed or blocked, pressure rises very quickly. The result can be:
Blockages happen more often than most plants expect: a valve closed by mistake, a clogged filter, a cold and thickened liquid in the line, or a downstream control valve shutting suddenly.
Most gear pump relief valves are spring-loaded. A poppet or ball is held against a seat by a spring. Pump discharge pressure acts on the poppet. When that pressure exceeds the spring force, the poppet lifts and liquid flows through the valve back to the low-pressure side.
| Term | Meaning |
|---|---|
| Set pressure (cracking pressure) | The pressure at which the valve starts to open |
| Full-bypass pressure | The pressure at which the valve passes the pump's full flow; always higher than the set pressure |
| Accumulation (pressure rise) | The difference between set pressure and full-bypass pressure |
| Reseat pressure | The pressure at which the valve closes again; usually slightly below set pressure |
When selecting or setting a valve, check the full-bypass pressure, not just the cracking pressure. This is the highest pressure your system will see when the discharge is completely blocked.
| Feature | Internal (built-in) relief valve | External relief valve |
|---|---|---|
| Location | Mounted on the pump cover or casing | In the discharge line, returning to tank |
| Where flow returns | Directly to the pump suction, inside the pump | To the supply tank |
| Suitable bypass time | Short periods only (seconds to a few minutes) | Longer periods, depending on tank size and heat |
| Heating of the liquid | Rapid, because the same liquid circulates inside the pump | Much lower, because liquid mixes with the tank |
| Cost and space | Compact, lower cost | Extra valve and return line |
| Direction | Usually works for one direction of rotation, unless a double-acting valve is fitted | Independent of pump rotation |
| Best use | Protection against accidental blockages | Systems where bypass is frequent or prolonged |
Do not use an internal relief valve for continuous bypass. All the motor's energy turns into heat in a small volume of liquid. Temperature can rise quickly enough to damage the seal, vaporise light liquids or degrade sensitive products.
If your pump runs in reverse at any point, check that the relief valve is arranged for that direction. See Reversing a Gear Pump for more.
A gear pump transfers furnace oil. Normal discharge pressure is 6 bar, rising to 7 bar on cold mornings. The pump and pipework are rated for 12 bar.
Safety: testing a relief valve means raising system pressure. Use a calibrated pressure gauge close to the pump discharge, keep people clear, and follow your plant's safety procedures. Do this only with a trained technician.
| Symptom | Likely cause | Fix |
|---|---|---|
| Pump flow lower than expected | Relief valve set too low, opening in normal running | Raise the setting within the system limits |
| Liquid and pump overheating | Valve bypassing continuously, often internal valve | Check for a downstream blockage; raise setting or fit an external valve to tank |
| Chattering or hammering noise | Set pressure too close to operating pressure; pulsation; undersized valve | Increase margin; check valve size and pipework |
| Pressure rises above setting | Valve stuck, spring too stiff, valve undersized for full flow | Service the valve; fit correct spring or larger valve |
| Valve leaks after closing | Dirt or wear on seat and poppet | Clean or lap the seat; replace worn parts |
| Motor trips when discharge closes | Full-bypass pressure too high for motor | Lower setting or upgrade motor |
For other causes of low flow and noise, see our gear pump troubleshooting guide.
Using the relief valve to reduce flow wastes energy and heats the liquid. To control gear pump flow, change the speed with a variable frequency drive (VFD) or gearbox, or use a properly sized bypass control valve returning to the tank.
Running against high pressure also loads the shaft seal. If the relief setting is high, confirm that the mechanical seal is rated for that pressure.
Unique Pump Systems supplies gear pumps with built-in relief valves and can advise on external relief arrangements for your system.
A gear pump is positive displacement, so it keeps delivering liquid even when the discharge is blocked. Pressure rises until a pipe, seal, coupling or motor fails. A relief valve opens at a set pressure and diverts the flow to protect the system.
Typically 10% to 20% above the maximum normal operating pressure, or at least about 1 to 2 bar above it, while keeping the full-bypass pressure below the rated pressure of the pump, pipework and motor.
An internal relief valve is built into the pump and returns flow to the pump suction, so it is only suitable for short blockages. An external relief valve sits in the discharge line and returns flow to the tank, so it can handle longer bypass periods with less heating.
Only for a short time with an internal valve, because the recirculating liquid heats up quickly. For frequent or long bypass, use an external relief valve that returns to the tank.
With a gauge at the pump discharge, briefly restrict the discharge and note the pressure at which it stops rising. Adjust the screw in small steps, usually clockwise to increase pressure, lock the nut and recheck. Follow safety procedures and keep the closed-valve time short.
Chattering usually means the set pressure is too close to the operating pressure, the system has strong pressure pulsation, or the valve is incorrectly sized. Increasing the margin or correcting the valve size usually solves it.
No. A relief valve is a safety device. Using it to control flow wastes energy and heats the liquid. Use a VFD, gearbox or a dedicated bypass control valve instead.
Usually not. An AODD pump stalls when discharge pressure equals the air supply pressure, so it limits its own maximum pressure.
A correctly selected and set relief valve is the cheapest insurance a gear pump system can have. Use internal relief valves for short, accidental blockages and external valves returning to the tank for longer bypass. Set the valve above normal operating pressure but below every component's rating, check the full-bypass pressure and motor load, and never use it to control flow.
Need help choosing or setting a relief valve? Contact Unique Pump Systems with your system details.