Unique Pump Systems, Kailash Industrial Complex, Vikhroli (W)

Unique Pump Systems, Kailash Industrial Complex, Vikhroli (W)

Gear Pump Relief Valve

Home Blog Gear Pump Relief Valve

Gear Pump Relief Valve: How It Works, Internal vs External, and How to Set the Pressure

Gear Pump Relief Valve Guide

Reviewed by the Unique Pump Systems engineering team | Updated November 2026

Quick Answer: A gear pump relief valve protects the pump, motor and pipework from overpressure. Because a gear pump is positive displacement, it keeps pushing liquid even when the discharge is blocked, so pressure rises until something fails. The relief valve opens at a set pressure and returns flow to the suction or to the tank. A common rule is to set it about 10% to 20% above the maximum normal operating pressure, and always below the rated pressure of the pump and system. An internal relief valve is for short-term protection only; continuous bypass needs an external valve returning to the tank.

Almost every gear pump needs a relief valve, yet it is one of the most misunderstood parts of a pumping system. Set too low, it wastes flow and heats the liquid. Set too high, or blocked, it offers no protection at all. This guide explains how gear pump relief valves work, the difference between internal and external valves, how to set the pressure correctly, and how to diagnose common relief valve problems.

Key Takeaways

  • A positive displacement pump must never run against a closed discharge without pressure protection.
  • Internal (built-in) relief valves recirculate liquid inside the pump. They protect against short blockages only.
  • External relief valves return liquid to the supply tank and can handle longer bypass periods.
  • Set the valve above the maximum operating pressure but below the pump, motor and pipework limits.
  • A relief valve is a safety device, not a flow control valve.

Why Gear Pumps Need a Relief Valve

A centrifugal pump that runs against a closed valve simply reaches its shut-off head. A gear pump does not have a shut-off point. Each revolution moves a fixed volume of liquid, so if the discharge is closed or blocked, pressure rises very quickly. The result can be:

  • Burst hoses, pipes, filters or gauges
  • Overloaded and tripped (or burnt) motors
  • Broken shafts, gears or couplings
  • Blown gaskets and shaft seal failure
  • A serious safety risk to people nearby

Blockages happen more often than most plants expect: a valve closed by mistake, a clogged filter, a cold and thickened liquid in the line, or a downstream control valve shutting suddenly.

How a Gear Pump Relief Valve Works

Most gear pump relief valves are spring-loaded. A poppet or ball is held against a seat by a spring. Pump discharge pressure acts on the poppet. When that pressure exceeds the spring force, the poppet lifts and liquid flows through the valve back to the low-pressure side.

TermMeaning
Set pressure (cracking pressure)The pressure at which the valve starts to open
Full-bypass pressureThe pressure at which the valve passes the pump's full flow; always higher than the set pressure
Accumulation (pressure rise)The difference between set pressure and full-bypass pressure
Reseat pressureThe pressure at which the valve closes again; usually slightly below set pressure

When selecting or setting a valve, check the full-bypass pressure, not just the cracking pressure. This is the highest pressure your system will see when the discharge is completely blocked.

Internal vs External Relief Valves

FeatureInternal (built-in) relief valveExternal relief valve
LocationMounted on the pump cover or casingIn the discharge line, returning to tank
Where flow returnsDirectly to the pump suction, inside the pumpTo the supply tank
Suitable bypass timeShort periods only (seconds to a few minutes)Longer periods, depending on tank size and heat
Heating of the liquidRapid, because the same liquid circulates inside the pumpMuch lower, because liquid mixes with the tank
Cost and spaceCompact, lower costExtra valve and return line
DirectionUsually works for one direction of rotation, unless a double-acting valve is fittedIndependent of pump rotation
Best useProtection against accidental blockagesSystems where bypass is frequent or prolonged

Do not use an internal relief valve for continuous bypass. All the motor's energy turns into heat in a small volume of liquid. Temperature can rise quickly enough to damage the seal, vaporise light liquids or degrade sensitive products.

If your pump runs in reverse at any point, check that the relief valve is arranged for that direction. See Reversing a Gear Pump for more.

How to Choose the Relief Valve Set Pressure

  1. Find the maximum normal operating pressure. Include the highest viscosity (coldest condition) and the most restrictive filter condition.
  2. Add a margin. Typically 10% to 20% above the maximum operating pressure, or at least about 1 to 2 bar, so the valve does not open in normal running.
  3. Check the upper limits. The full-bypass pressure must stay below the rated pressure of the pump, pipework, hoses, filters and instruments.
  4. Check the motor. The motor must be able to drive the pump at full-bypass pressure without overloading.

Worked example

A gear pump transfers furnace oil. Normal discharge pressure is 6 bar, rising to 7 bar on cold mornings. The pump and pipework are rated for 12 bar.

  • Maximum operating pressure: 7 bar
  • Set pressure: 7 × 1.15 ≈ 8 bar
  • Full-bypass pressure (with accumulation): about 9 to 10 bar, below the 12 bar rating
  • Motor check: power at 10 bar = flow (L/min) × 10 ÷ 600 ÷ efficiency, must be within the motor rating

How to Set or Check a Gear Pump Relief Valve

Safety: testing a relief valve means raising system pressure. Use a calibrated pressure gauge close to the pump discharge, keep people clear, and follow your plant's safety procedures. Do this only with a trained technician.

  1. Fit a pressure gauge between the pump discharge and the first valve.
  2. Start the pump with the discharge valve open and the system at normal temperature.
  3. Slowly close the discharge valve while watching the gauge. Do not close it fully if the valve's setting is unknown and the system rating is low.
  4. Note the pressure at which the gauge stops rising. This is roughly the full-bypass pressure.
  5. Open the discharge valve. Adjust the relief valve screw (clockwise usually increases pressure) in small steps, locking the nut after each change.
  6. Repeat the check, keeping the closed-valve period short to limit heating.
  7. Record the final setting and seal or tag the adjuster to prevent unauthorised changes.

Common Relief Valve Problems and Fixes

SymptomLikely causeFix
Pump flow lower than expectedRelief valve set too low, opening in normal runningRaise the setting within the system limits
Liquid and pump overheatingValve bypassing continuously, often internal valveCheck for a downstream blockage; raise setting or fit an external valve to tank
Chattering or hammering noiseSet pressure too close to operating pressure; pulsation; undersized valveIncrease margin; check valve size and pipework
Pressure rises above settingValve stuck, spring too stiff, valve undersized for full flowService the valve; fit correct spring or larger valve
Valve leaks after closingDirt or wear on seat and poppetClean or lap the seat; replace worn parts
Motor trips when discharge closesFull-bypass pressure too high for motorLower setting or upgrade motor

For other causes of low flow and noise, see our gear pump troubleshooting guide.

Relief Valve Is Not a Flow Control Valve

Using the relief valve to reduce flow wastes energy and heats the liquid. To control gear pump flow, change the speed with a variable frequency drive (VFD) or gearbox, or use a properly sized bypass control valve returning to the tank.

Do Other Pumps Need Relief Valves?

  • lobe pump: yes. Lobe pumps are positive displacement and need the same protection.
  • aodd pump: usually no. An AODD pump stalls when discharge pressure reaches the air supply pressure, so it protects itself.
  • Centrifugal Pump: not for overpressure, but it still needs a minimum flow bypass if it may run against a closed valve for long.

Running against high pressure also loads the shaft seal. If the relief setting is high, confirm that the mechanical seal is rated for that pressure.

Information to Share With Your Supplier

  • Liquid, viscosity range and temperature
  • Flow rate and maximum operating pressure
  • Rated pressure of pipework, hoses and filters
  • Whether the pump ever runs in reverse
  • How often and how long the discharge may be blocked
  • Preference for internal, external or both

Unique Pump Systems supplies gear pumps with built-in relief valves and can advise on external relief arrangements for your system.

Frequently Asked Questions

Why does a gear pump need a relief valve?

A gear pump is positive displacement, so it keeps delivering liquid even when the discharge is blocked. Pressure rises until a pipe, seal, coupling or motor fails. A relief valve opens at a set pressure and diverts the flow to protect the system.

What pressure should a gear pump relief valve be set at?

Typically 10% to 20% above the maximum normal operating pressure, or at least about 1 to 2 bar above it, while keeping the full-bypass pressure below the rated pressure of the pump, pipework and motor.

What is the difference between an internal and external relief valve?

An internal relief valve is built into the pump and returns flow to the pump suction, so it is only suitable for short blockages. An external relief valve sits in the discharge line and returns flow to the tank, so it can handle longer bypass periods with less heating.

Can a gear pump run with the relief valve open?

Only for a short time with an internal valve, because the recirculating liquid heats up quickly. For frequent or long bypass, use an external relief valve that returns to the tank.

How do I adjust a gear pump relief valve?

With a gauge at the pump discharge, briefly restrict the discharge and note the pressure at which it stops rising. Adjust the screw in small steps, usually clockwise to increase pressure, lock the nut and recheck. Follow safety procedures and keep the closed-valve time short.

Why is my gear pump relief valve chattering?

Chattering usually means the set pressure is too close to the operating pressure, the system has strong pressure pulsation, or the valve is incorrectly sized. Increasing the margin or correcting the valve size usually solves it.

Can I use the relief valve to control gear pump flow?

No. A relief valve is a safety device. Using it to control flow wastes energy and heats the liquid. Use a VFD, gearbox or a dedicated bypass control valve instead.

Does an AODD pump need a relief valve?

Usually not. An AODD pump stalls when discharge pressure equals the air supply pressure, so it limits its own maximum pressure.

Conclusion

A correctly selected and set relief valve is the cheapest insurance a gear pump system can have. Use internal relief valves for short, accidental blockages and external valves returning to the tank for longer bypass. Set the valve above normal operating pressure but below every component's rating, check the full-bypass pressure and motor load, and never use it to control flow.

Need help choosing or setting a relief valve? Contact Unique Pump Systems with your system details.

Unique Pump Systems

Kailash Industrial Complex, Vikhroli West, Mumbai

★★★★★4.4 out of 5 — Rated by verified clients on Google

"Excellent quality gear pumps. Delivered on time, every time. Highly recommend for industrial applications."

— Verified Google Review

"Best mechanical seal manufacturer in Mumbai. Replaced our imported seal with their local equivalent — same performance, much better pricing."

— Verified Google Review
Write a Review on Google View on Google Maps
Rated 4.4★ on Google
★★★★★
See our reviews →